Fujitsu Comfort Range
Ideal for mid-sized rooms, the Fujitsu’s Comfort range of wall mounted heat pump/air conditioning units provide energy efficient, all-year-round climate control for the home and uses R32 refrigerant, which has a 67 percent lower ‘Global Warming Potential Factor’ whilst still maintaining the performance of the air conditioner*. Other features include super-quiet mode and powerful operation mode.
- All DCWith All DC, electricity loss is decreased and power consumption reduced.
- Auto RestartShould there be a temporary loss of power, the unit will automatically restart itself in the same operating mode, once the power is restored.
- Auto Shut LouvreThe auto shut louvres close or open automatically when the unit stops or starts.
- Auto ChangeoverThe unit automatically switches between operating modes based on the temperature setting and room temperature.
- Automatic LouvreThe position of the louvres is set automatically to match the operating mode. It is also possible to adjust the louvres using the remote control.
- Blue Fin Heat ExchangerCorrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchanger.
- Economy ModeLimits the maximum operation current, and performs operation with the power consumption suppressed.
- Filter SignSelect appropriate intervals for displaying the filter sign on the indoor unit according to the estimated amount of dust in the air of the room.
- i-PAMi-PAM inverter technology enables high output and high efficiency performance.
- On-Off TimerON-OFF timer can be set to operate once every 24 hours.
- Powerful ModePowerful mode will operate the indoor unit fan and outdoor unit compressor at maximum operation to quickly make the room conditioned and comfortable.
- Program TimerThis timer allows selection of one of four options. ON, OFF, ON ––> OFF, or OFF ––> ON.
- Sleep TimerThe micro-processor gradually changes the room temperature, allowing you to sleep comfortably at night.
- Super Quiet ModeThe indoor units fan can operate at a low speed to produce quieter operation.
- Up/Down Swing LouvreThe up/down louvre automatically swings up and down.
- V-PAMv-PAM inverter technology increases the maximum output of the compressor significantly and enables high power and high efficiency.
- Washable PanelDust that accumulates on the air conditioner can be easily cleaned with a damp cloth.
- 0.5°C IncrementsThe remote control now allows you to set temperature in 0.5°C increments, giving you a better control on your comfort
Indoor unit | ASTH22KNTA |
Outdoor unit | AOTH22KNTA |
Operation Type | Reverse Cycle |
Power Source V/Ph/Hz | 230 / 1 / 50 |
Cooling Capacity kW (Rated (Min – Max)) | 6.00 (0.9 – 6.5) |
Heating Capacity kW (Rated (Min – Max)) | 6.50 (0.9 – 7.7) |
Input Power Cooling kW (Rated (Min – Max)) | 1.78 (0.12 – 2.07) |
Input Power Heating kW (Rated (Min – Max)) | 1.85 (0.12 – 2.4) |
EER Cooling kW/kW | 3.37 |
COP Heating kW/kW | 3.51 |
Star Rating Cooling (0-10) (Hot / Average / Cold) | 3.5 / 3.5 / 3.5 |
Star Rating Heating (0-10) (Hot / Average / Cold) | 3 / 2 / 1.5 |
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) | 5.963 / 6.36 / 7.187 |
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) | 4.901 / 3.982 / 3.268 |
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) | 5.377 / 5.101 / 5.495 |
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) | 4.922 / 4.379 / 3.599 |
Running Current amps (Cooling / Heating) | 7.9 / 8.2 |
Moisture Removal l/hr | 2.9 |
Indoor Sound Pressure Cooling dBA (High / Quiet) | 48 / 31 |
Indoor Sound Pressure Heating dBA (High / Quiet) | 48 / 31 |
Outdoor Sound Pressure dBA (Cooling / Heating) | 54 / 53 |
Outdoor Sound Power dBA | 68 |
Air Circulation (Indoor – High Fan) Cooling l/sec | 244 |
Air Circulation (Indoor – High Fan) Heating l/sec | 244 |
Indoor Unit Dimensions mm (Height x Width x Depth) | 270 x 834 x 232 |
Indoor Unit Weight kg | 11.00 |
Outdoor Unit Dimensions mm (Height x Width x Depth) | 632 x 799 x 290 |
Outdoor Unit Weight kg | 36.00 |
Piping Connects mm Ø (Liquid / Gas) | 6.35 / 12.7 |
Pipe Length m (Max (Precharged)) | 25 (15) |
Max Height Difference m | 20 |
Operation Range Cooling °CDB (Min to Max) | -10 to 50 |
Operation Range Heating °CDB (Min to Max) | -15 to 24 |
Refrigerant Type | R32 |
Refrigerant Amount g | 960 |